Filter plate is the ideal sludge and sewage filter equipment, what are the main factors that harm the operation process specification?
Reasons for slow operation of filter plate:
1. The hydraulic transmission system is tired
The hydraulic transmission system provides a strong driving force for all operations of machinery and equipment, including the extrusion processing of the filter plate of the filter machine, the pulling back of the push plate, and the operation of the pull plate car. It all depends on the hydraulic pressure of the machinery and equipment. The transmission system improves a strong driving force to carry out,
Therefore, in the process of using the filter plate, the hydraulic transmission system of the machine equipment has high working frequency and high tensile strength. Naturally, it is a prefabricated component that is easy to fatigue in the machine equipment.
Hydraulic drive system tired solution:
Introduce more oil or remove the oil to lower the ambient temperature of the oil under continuous high temperature conditions to ensure that the ambient temperature of all systems slowly drops. When the ambient temperature of the oil drops, the ambient temperature of the sealing ring of the hydraulic cylinder in the hydraulic machine returns to normal, which can repair its sealing effect and prevent the hydraulic cylinder from being tired due to oil flow.
2. Too many oil stains and stains on the guiding rod
There are too many oil stains and stains on the guiding rod, the sliding friction between the guiding rod and the touching part is too large, and the main oil passage of the hydraulic cylinder of the hydraulic machine is abnormal. The filter plate of the filter is similar to the difficulties in the whole process of use. The guiding rod should be cleaned immediately and coated with vegetable butter,
To ensure its lubricity, especially to pay attention to the point that it is forbidden to apply thin oil on the guiding rod, because the thin oil is easy to fall off and makes the bottom very slippery, and it is very easy for the staff to fall down during the operation and maintenance. Attention should be paid.
3. Tired cable line
When the ambient temperature of the circuit is found to be too high, it means that the filter plate of the filter is already running under load, and the workload or pressure range of the machine and equipment is greatly beyond the scope of the machine and equipment. Then the diesel engine that converts electric energy into driving force requires a higher circuit, and the natural circuit will overheat.